Resona 6

Premium Ultrasound System

New Waves in Ultrasound Innovation



Overview

Since the company was founded, Mindray is continuously exploring new ways to improve diagnostic confidence. Powered by the most revolutionary ZONE Sonography® Technology, Resona 6’s new ZST+ platform brings ultrasound image quality to a higher level by zone acquisition and channel data processing. As well as ZST+ powered premium image quality, Resona 6 also provides essential clinical features with proven performance, most intelligent fetal CNS plane acquisition and most intuitive gesture-based operation. All of these above have built up Resona 6 as the achievable premium solution to address challenges of clinical accuracy and efficient diagnosis in today’s demanding and overburden hospital environments.



  Contact Us



Core Platform and Technology


The channel data based ZST+ is an extraordinary innovation, representing an ultrasound evolution. Transforming ultrasound metrics from conventional beamforming to channel data based processing, ZST+ is able to deliver multiple imaging advances: Advanced Acoustic Acquisition, Dynamic Pixel Focusing, Sound Speed Compensation, Enhanced Channel Data Processing and Total Recall Imaging.

 



Advanced Acoustic Acquisition


By transmitting and receiving a relatively smaller number of large zones, Advanced Acoustic Acquisition extracts more information from each acquisition, 10 times faster than a conventional line-by-line beamforming method.

 


 



Dynamic Pixel Focusing


Dynamic Pixel Focusing technology allows the Resona 6 to achieve extreme uniformity in pixel level throughout the whole field of view. Now there's no need to adjust the focal positions to achieve uniformity across patient exams.



 


Sound Speed Compensation


By retrospectively analyzing complete channel data stored in channel data memory, the Resona 6 is able to intelligently choose the optimal sound speed to improve image accuracy even with tissue variation, allowing for adaptive tissue-specific optimization.


 


 

Enhanced Channel Data Processing


Channel data based ZST+ provides Enhanced Channel Data Processing for greatly improved imaging clarity. By multiple and retrospective channel data processing, it makes the best use of acoustic information for image improvement.

· HD Scope: higher definition image within ROI
· Coherent Spatial Synthesis: further improved image quality of spatial compound




Total Recall Imaging


As ZST+ captures and stores the complete acoustic raw data set, Total Recall Imaging allows system to do retrospective processing on channel data and also permits users to modify numerous imaging parameters on stored images to maximize clinical output.




Advanced Features

UWN (Ultra-Wideband Non-linear) Contrast Imaging


UWN+(Ultra-Wideband Non-linear Plus) CEUS enables the Resona 6 to detect and utilize both 2nd harmonic and non-linear fundamental signals, generating significantly enhanced CEUS images, resulting in greater sensitivity of minor signals and longer agent duration with lower MI.





RIMT (RF-Data IMT)


Based on radio frequency data (RF-Data) with rawer acoustic information, RIMT provides automatic and real-time IMT measurements with extremely higher accuracy of 5?m, more quantifications within six heart cycles, and less dependence on image quality for greatly improved diagnostic confidence.





Natural Touch Elastograhpy


Based on Mindray’s exclusive elastography algorithm, Natural Touch Elastography enables higher stiffness sensitivity and better reproducibility, reducing dependence on operator's scanning skill and improving clinical output and user experience for higher clinical utility. Particularly unique shell analysis, a very useful tool to evaluate benign and malignant lesions, provides relative strain ratio between surrounding tissue and the lesion, indicating status of the infiltration of cancer cells into peritumoral tissue.






Smart Planes


Mindray’s exclusive pioneering technology positions the Resona 6 as the industry’s first ultrasound system to allow fully automatic and accurate detection of the most significant planes and frequently used measurements of fetal CNS, leading to intelligent diagnosis, improved throughput, and reduced user dependency.

Smart Planes provides a user-friendly tool that greatly improves scanning efficiency through increased accuracy coupled with automated operation. With a simple button click on a 3D fetal brain volume image, the standard CNS scanning planes (MSP, TCP, TTP and TVP) and a range of related anatomical measurements (BPD, HC, OFD, TCD, CM and LVW) are obtained immediately.






Smart FLC


Smart FLC automatically detects the number of follicles and calculates each volume from a 3D ovarian volume image, assuring accurate assessment of follicles, especially with IVF exams.




Smart OB/NT


Automatic measurements of the most frequently examined parameters, including BPD, HC, FL, AC, OFD and even NT as early as 11 weeks, are available with a single click for higher productivity and reproducibility.




Ergonomics


The Resona 6 is designed around you. Gesture-based operation opens up a new trend in cart-based ultrasound with an agile, smart, and intuitive user experience beyond your expectations. Resona 6 allows ultrasound professionals to do more much faster, putting patient care first through better user experience driven by inspired innovations.

  • 21.5” high resolution LED monitor
  • 12.1” tilting multi-gesture touch screen
  • 3 level temperature adjustable gel warmer
  • Flexible and user-friendly control panel
  • Pinless transducer with light indicator
  • Separate pedals for swivel and rolling lock





Clinical Images

  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
Transducers

Convex Transducer




  • C5-1U


  • SC5-1U


  • SC8-2U



Linear Transducer



  • L11-3U


  • L14-6WU


  • LM16-4U



Phased array Transducer



  • SP5-1U



Endocavity Transducer



  • V11-3HU



Volume Transducer




  • D8-4U


  • DE10-3U