MEDIVENT GOLD - ICU VENTILATOR

MEDIVENT GOLD - ICU VENTILATOR

In India, we are the top distributor and marketer of the Medivient gold- ICU Ventilator at affordable costs. This newborn ventilator is incredibly portable and has a sizable 12.1-inch graphical LCD. It is available in several sizes and characteristics based on what the customer wants. ICU ventilators have been put in several multispecialty hospitals, clinics, assisted living facilities, and other locations since its founding. Once installed, you won't need to worry about maintenance because it will continue to function comfortably even in an emergency.

Product Details:

Certifications

Certifications for the product ICMED 13485 plus
Certificate number and date 302120718 & 11.07.2020
Conformity to quality management standards ISO 9001 & ISO 13485
Conformity to electrical safety standards IEC 60601-1 or ISO 80601-2-12 or BIS equivalent

Performance Parameters

Purpose Ventilators are used to provide invasive ventilation (e.g., with an endotracheal tube or tracheostomy tube) or noninvasive ventilation (e.g., with a face mask). This device provides temporary or permanent respiration for patients who cannot breathe on their own, or who require assistance maintaining adequate ventilation
Suitable for ICU Yes
Patient type Adult & Pediatric
Type of technology Compressor
If technology is compressor-based The compressor should be standalone
Tidal volume 50 ml or less - 1500 ml or more
Peak Respiratory rate in breaths/min 60
Trigger mechanism Both pressure and flow
Trigger flow sensitivity 1 to 10 LPM
Peak flow rate, LPM 150
FiO2 21-100%
IE ratio 1:4 to 4:1
PEEP/CPAP, cm H2O (increments of 1cm H2O) 0-30
Programmable/adjustable sign Yes
Ventilation monitoring facility Microprocessor Controlled ventilator with active exhalation valve
Leak volume compensation Yes
Volume accuracy 2-3% of full scale between 10 to 80 LPM
Inspiratory time 0.3 to 5 sec
Pressure support 0-40 cm H2O
Inspiratory pause Yes
Auto 100% Increase O2 button Yes
Control panel lock No
Facility for double lung ventilation No
Undergo Automatic calibration system on start-up Yes

Modes and Monitored Parameters

Loops displayed Flow/Volume, Pressure/Volume, Pressure/Flow
Graphic displays have automatic scaling facilities for waves Yes
Maximum trending time 72 hour
Lung recruitment tools (PV loops)/OLT(Open lung tools) No
Lung mechanics visualization tool No
Capnography/CO2 monitoring No
Esophageal/transpulmonary pressure monitoring No
Stress index No
Modes of ventilation C-CMV, PC-SIMV, PSV, VC-SIMV, VC-CMV, PRVC, ACV, CPAP,& BPAP (pressure support ventilation can be used in place of CPAP & BPAP
ASV(Adaptive support ventilation) ALT No
APRV Yes
MMV +PSV /ASV or ALPV or Automode No
Automatic weaning mode No
Displayed parameters Respiratory phase and type, Exhaled tidal & minute volume, Peak inspiratory pressure, Mean airway pressure, PEEP, Tidal volume, Leak volume, Minute volume, Spontaneous minute volume, FiO2 (analyzed %), Respiratory rate, Inspiratory time, Expiratory time, IE ratio, mean & Plateau Pressure
RSBI No
Static compliance and resistance No
Low inflection point (LPI) and upper inflection point (UPI) Yes

Alarms

Patient alarms Low/high FiO2, Low/high minute volume, Low inspiratory pressure, High pressure, Low PEEP, High PEEP, Apnea, Continuous high pressure/occlusion, Inverse IE, High respiratory rate, Breathing circuit disconnect
Equipment alarms Gas-supply failure, Power failure, Vent inoperative, Low battery, Self-diagnostic
Non-forced Slow Vital Capacity No
Physiologic Dead space No
Imposed work of Breathing ( WOBi) No
Expiratory Time constant ( Tcexp) No
Compliance with static and dynamic Yes
Inspired and expired resistance No
Inspiratory and expiratory hold Yes
Spontaneous frequency Yes
The expiratory block is autoclavable and no routine calibration is required Yes
Power disconnected Power supply unplugged
Patient Disconnected "PIP < (Desired Pressure x 0.6)"
High Inspiratory Pressure "PIP < (Desired Pressure x 0.6)"
High PEEP "PEEP > Set PEEP + 2 or 6 Consecutive cycles"
High Respiratory Rate RR > 70
Power Sensor Failure The power sensor fails to respond
Ventilator Temperature Error The core temperature of a ventilator CPU greater than 85 °C
System Failure (Safe Mode) "Vital components inactive"
Low Tidal Volume VTi < Set VT * 0.75 for 6 consecutive cycles
Alarm history >100 alarms or minimum of 16 alarms /event Yes
Time for Displayed Trends Values 48 hours

Power requirement and data management

RS 232 output port No
USB/Memory card No
Availability of Remote alarm/display port Yes
Facility to Report (vent alarms and patient status) Yes
HLT Compliant output No
Type of colored display LCD
The display should be a touch screen No
Size of screen 10 inches or more
Power supply 220-240 V , 50 Hz AC single phase
Length of Power cord 3 meter
Provision of UPS Yes
Battery backup time (tolerance of 30 minutes minus and side allowed) 30 hour
Type of battery Lithium-ion
Power of battery in watt/hr 60
Programmable ultrasonic nebulizer External

Additional Accessories

Patient tubing for Adult and pediatric 2 each
NIV mask(Reusable)- medium and large 2 Each
Type of flow sensor Reusable
No reusable flow sensor 2
No disposable flow sensor 50
Autoclavable exhalation valve/expiratory casette / filter 2
Humidifier: Servo controlled with digital monitoring of inspired gas temperature with heating wire and arm holder 1
Trolley for ventilator with circuit holding arm Yes
Test lung for adult and pediatric 1 Each

Miscellaneous Parameters

Warranty (The option of comprehensive warranty is available through bidding only, which if opted will supersede the normal warranty in the catalog) 1 year
Compressor certification BIS
The compressor shall provide oil-free Medical air, with Peak output flow and Air quality complying with ISO compressed air purity class Yes
Medical Air Compressor should automatically activate in the event of wall air supply loss and replacement of internal filters should be performed without removing the compressor, have a washable air filter Yes
The compressor should be from the same manufacturer or OEM NA Compressor of different makes with the seller taking responsibility of the functioning of the both compressor & ventilator
Certification to supply the spare parts OEM/Reseller ( if supplied by reseller shall ensure uninterrupted availability of all spares for 10 years)
Availability of toll-free facility for technical support maintained by OEM or authorized agencies Yes
User/Technical/Maintenance manuals to be supplied in English in hard and soft copy Yes
Details of equipment and procedures required for local calibration and routine maintenance to be supplied and advanced maintenance task documentation is also to be furnished Yes
List of spares List of important spares and accessories, with their part numbers and price lists to be supplied to the buyer at the time of supplying the equipment
Installation and training Installation of equipment and training to be provided after completing supplies before acceptance
Service Center (24x7 service) The Principal Manufacturer must have a direct Presence/approved service center In India
Copies of reports and certifications are to be furnished to the buyer on demand at the time of supplies Yes

There are lots of higher models available with us but due to price sensitive market, details of the same are not shared on our website. To know more about these models contact us now!
Our Products

We known for their bespoke design service where an extra level of detail is added to each of their projects. Creative, receptive and not afraid to push the boundaries of the best possible.

Contact us
Get Catch Us From Here. Right Now

Location

S S MEDICORP PRIVATE LIMITED
124, Rajdanga NabapallyKasba Thana,
Kolkata - 700078
West Bengal INDIA

Order On Whatsapp